  1.                  MICROPOLIS 1650 DISK DRIVE
  2.                        SPECIFICATIONS
  3.  
  4.                                        Model Number
  5. Unformatted Capacity:     1653-4     1653-5     1654-6     1654-7
  6.  
  7.   Total Mbytes             104.0      130.0      156.1      182.1
  8.   Disk Platters                3          3          4          4
  9.   Read/Write Heads             4          5          6          7
  10.   Cylinders               ---------------- 1249 -----------------
  11.   Bytes per track         -------------- 20,832 -----------------
  12.  
  13.  
  14. Formatted Capacity
  15.  
  16.   Total Mbytes              92.0      115.0      138.0      161.0
  17.   Bytes per Sector        ----------------- 512 -----------------
  18.   Sectors per Track       -----------------  36 -----------------
  19.  
  20. PC Drive Types.
  21.  
  22.   If you are using third-party installation software or an board
  23.   BIOS on the controller, follow the instructions included with
  24.   the software or controller. Otherwise, examine the entries in 
  25.   your drive table and find the type that most resembles the head
  26.   and cylinder parameters of the drive without exceeding these
  27.   parameters.
  28.  
  29. Performance Specifications
  30.  
  31.   Seek Time (including settling time)      Track-to-Track  4 msec
  32.                                            Average        16 msec
  33.                                            Maximum        37 msec
  34.   Avg Rotational Latency                                8.33 msec
  35.   Rotational Speed                              3600 rpm +/- 0.5%
  36.   Data Transfer Rate                                 10 Mbits/sec
  37.   MTBF                                              150,000 hours
  38.   Positioner                     Fully balanced rotary voice coil
  39.   Parking                                 Automatic park and lock
  40.  
  41. General Functional Specifications
  42.  
  43.   Interface                                                  ESDI
  44.   Sectoring (see W1 description, below)              Hard or Soft
  45.   Write Precompensation Start Cylinder                     1249 *
  46.   Reduced Write Current Start Cylinder                     1249 *
  47.   Landing Zone                                               1249
  48.   Mounting Plane                                  Any orientation
  49.  
  50.   * These are effectively turned off by specifying a non-existent
  51.   cylinder. Some systems accomplish this by using a value of "-1"
  52.  
  53. Power Requirements 
  54.  
  55.   +12V +/-5%                                             0.9A Avg
  56.                                       (2.0A max. during start-up)
  57.   +5V +/-5%                                              0.7A avg
  58.   Power dissipation, typical                             14 Watts
  59.  
  60. Drive Addressing and Interface Termination
  61.  
  62.    NOT                                         
  63.    USED       J2                   J1             J3            
  64.    ____   ___________       _________________   ________  Power
  65.   |    | |         |1|     |               |1| || Power | (under
  66.   |    |_|           |_____|                 |_| -------| board)
  67.   |                                                     |
  68.   |                                                     |
  69.   |                 Terminator                          |
  70.   |                                                     |
  71.   |                                                     |
  72.   |                                                     |
  73.   |                                                     |
  74.   |                                                     |
  75.   |                                                     |
  76.   |    DA1                                              |
  77.   |    DA2                                              |
  78.   |    DA3                    (Component side)          |
  79.   |     W5                                              |
  80.   |     W4                                              |
  81.   |     W3                                              |
  82.   |     W2                                              |
  83.   |     W1                                              |
  84.  
  85. RN1 Interface Terminator
  86.   The Interface Terminator factory installed at RN1 will provide
  87.   proper termination for the interface lines. When daisy-chaining
  88.   multiple drives, leave the terminator installed  only in the last
  89.   physical drive on the daisy chain; remove the terminator from
  90.   each of the other drives. In most PC/AT installations, the C:
  91.   drive is  actually at the end of the cable and should retain the
  92.   terminator.
  93.  
  94. DA1, DA2, DA3 Drive Address Jumpers
  95.   The drive address jumpers are identified as DA1, DA2 and DA3.
  96.   Address selection is binary, as shown in the table below. The
  97.   ESDI controllers's documentation will specify the drive address
  98.   to use.
  99.  
  100.    Drive            Select Jumpers
  101.   Address        DA3     DA2     DA1
  102.   -------        ---     ---     ---
  103.      1           out     out      in
  104.      2           out      in     out
  105.      3           out      in      in
  106.      4            in     out     out
  107.      5            in     out      in
  108.      6            in      in     out
  109.      7            in      in      in
  110.  
  111.   "Drive address 0" (no jumper at DA1, DA2, or DA3) is a "deselect"
  112.   (i.e., no drive selected). Drives are factory configured as Drive
  113.   Address 1. For many multiple drive installations, each drive must
  114.   have a unique address. An exception is that for every drive in
  115.   a PC/AT installation, verify that only Drive Address is at DA2;
  116.   move  the jumper if necessary(the special twisted interface cable 
  117.   that is generally used takes care  of assigning a unique address
  118.   to each drive). PC/AT controller can typically support a maximum
  119.   of two drives.
  120.  
  121. W5 Selects the Spindle Control Option.
  122.   W5 selects the spindle a control option. If W5 is installed, the
  123.   drive waits for a Start Spindle command (after power is  applied)
  124.   to start the spindle motor. If W5 is not installed (the factory
  125.   default configuration), the drive automatically starts the spindle
  126.   motor at power-on. W5 is not installed for PC/AT applications.
  127.  
  128. W1 Selects the Sectoring Mode.
  129.   If W1 is installed, the drive operates in the soft-sectored mode.
  130.   If W1 is not installed (the factory default configuration), the
  131.   drive operates in the hard-sector mode. W1 is not installed for 
  132.   most PC/AT in applications.
  133.  
  134. W2, W3, W4 Sector Size Option
  135.   The number of bytes per sector may be specified using the Set
  136.   Bytes Per Sector command or by selecting a default sector 
  137.   configuration with jumpers W2, W3, and W4 as follows:
  138.  
  139.        Jumpers            Sectors            Bytes/Sector
  140.     W4    W3    W2       Per Track       Formatted  Unformatted
  141.     ---   ---   ---      ---------       ---------  -----------
  142.     out   out   out         35              512          595
  143.  -------------------------------------------------------------
  144. | * out   out    in         36              512          578  |
  145.  -------------------------------------------------------------
  146.     out    in   out         19             1024         1096
  147.     out    in    in          9             2048         2314
  148.      in   out   out          5             4096         4166
  149.      in   out    in         32              512          651
  150.      in    in   out         64              256          325
  151.      in    in    in          1           20,832       20,832
  152.  
  153.   * This is the default (factory installed) configuration and is